Div_left:
- The type of anastomosis (iso or anti) does not show any significant clinical difference. Preference is surgeon related, however, iso peristaltic anastomosis is preferred.
- Closure of the common enterotomy is most commonly done by suture closure. A two layer, running absorbable suture, technique is the preferred method. A 3-0, 180 day, 15 cm in length with a CV23 needle V-lock is my preferred suture.
- The common enterotomy may be closed with the stapler as well
- The mesenteric defect is left open